Fire resistance & stability after fire

Is your building being renovated or given a new purpose? In that case, stricter fire resistance requirements often apply than under the original design. Sanacon inspects the existing structure, determines the current fire resistance, and provides targeted advice on measures to increase it. Has a fire occurred? Then we assess the residual load-bearing capacity so that you know whether repairs are sufficient or if reinforcement is necessary.

  • Assessment of post-fire stability | Forensic engineering by Sanacon
  • Beoordeling schade na brand bij gewapend beton - sanacon
  • Beoordeling schade na brand bij gewapend beton - sanacon
  • Forensic engineering after concrete fire damage | Sanacon
  • Beoordeling schade na brand bij gewapend beton - sanacon
Betonstructuur voor renovatie of herbestemming

Determining fire resistance during renovation or repurposing

When renovating or repurposing an existing building, the original fire resistance is often no longer sufficient. A new function generally entails stricter requirements, and without the original design data, it is unclear whether the structure meets them. Sanacon inspects the existing structure on-site and determines the current fire resistance of the load-bearing elements based on this assessment.

This investigation maps the relevant parameters: the effective concrete cover of the reinforcement, the concrete composition, the dimensions of the elements and, in the case of steel structures, the presence and condition of any fire-resistant protection. Where necessary, this is supplemented with material analysis, carried out by BETON+ , to confirm the exact material properties.

Based on this data, Sanacon calculates the current fire resistance per element and compares it with the required standard for the new function. Where a deficiency is identified, we provide targeted advice on the most effective measures to increase fire resistance. This may involve applying additional fire-resistant cladding, optimizing concrete cover during repair work, or other structural interventions, always tailored to what is technically feasible and economically justifiable for your project.

Beoordeling brandschade bij gewapend beton

Assessment of stability after fire

After a fire, the first question is always: is the structure still safe, and which elements have lost their load-bearing capacity? Sanacon conducts a thorough post-fire assessment to objectively evaluate the structural impact of the fire damage. This is done through visual inspection, targeted material testing, and a recalculation of the load-bearing capacity based on the actual damage determined.

We map out which elements have been superficially affected and which have suffered a significant loss of load-bearing capacity, for example due to concrete spalling, discoloration indicating high temperatures, or deformation of steel profiles. Where necessary, this is supplemented by BETON+ laboratory analysis, such as testing the residual strength of concrete samples exposed to the fire.

Based on this structural assessment, Sanacon formulates clear advice: which elements can retain their function without intervention, which require local repair, and which reinforcement or replacement is necessary to make the structure safe again.

Mathias Maes (links) en Tim Soetens (rechts), oprichters van Sanacon

We are happy to help you

Your structure deserves a future. Protection against deterioration, strengthening its load-bearing capacity, and extending its lifespan are crucial to prevent damage and high costs. Sanacon offers independent advice and innovative solutions to keep your structure sustainable and safe – today and for decades to come.